Épaisseur maximale de remblai

 

Diam Classes
Pression/
Spéciales
Épaisseur
Nominale
de Paroi
Épaisseur Maximale de Remblai
CONDITIONS DE POSE ( Voir conditions de pose dans la section d'installation)

Type 1 Type 2 Type 3 Type 4 Type 5
po mm CP CS po mm pi m pi m pi m pi m pi m
4 100 350 -
52
.25
.29
6.4
7.4
53
100+
16.0
30+
61
100+
19.0
30+
69
100+
21.0
30+
85
100+
26.0
30+
100+
100+
30+
30+
6 150 350 50
52
.25
.31
6.4
7.9
26
67
7.9
20.0
31
77
9.4
23.0
37
86
11.0
26.0
47
100+
14.0
30+
65
100+
20.0
30+
8 200 350 -
50
52
.25
.27
.33
6.4
6.9
8.4
16
25
47
4.9
7.6
14.0
20
30
54
6.1
9.1
16.0
25
36
62
7.6
11.0
19.0
34
46
77
10.0
14.0
23.0
50
64
99
15.0
20.0
30.0
10 250 350 -
50
52
.26
.29
.35
6.6
7.4
8.9
11
19
35
3.4
5.8
11.0
15
24
41
4.6
7.3
12.0
19
29
47
5.8
8.8
14.0
28
38
59
8.5
12.0
18.0
45
55
79
14.0
17.0
24.0
12 300 350 -
50
52
.28
.31
.37
7.1
7.9
9.4
10
17
30
3.0
5.2
9.1
15
22
35
4.6
6.7
11.0
19
27
41
5.8
8.2
12.0
28
36
53
8.5
11.0
16.0
44
52
71
13.0
16.0
22.0
14 350 250
300
350
-
-
-
50
52
.28
.30
.31
.33
.39
7.1
7.6
7.9
8.4
9.9
Non Recommandé
11
13
14
19
29
3.4
4.0
4.3
5.8
8.8
15
17
19
24
34
4.6
5.2
5.8
7.3
10.0
23
26
27
33
44
7.0
7.9
8.2
10.0
13.0
36
42
44
49
62
11.0
13.0
13.0
15.0
19.0
16 400 250
300
350
-
-
50
52
.30
.32
.34
.40
7.6
8.1
8.6
10.2
Non Recommandé
11
13
15
25
3.4
4.0
4.6
7.6
15
17
20
30
4.6
5.2
6.1
9.1
24
26
28
40
7.3
7.9
8.5
12.0
34
39
44
57
10.0
12.0
13.0
17.0
18 450 250
300

350
-
-
50
-
52
.31
.34
.35
.36
.41
7.9
8.6
8.9
9.1
10.4
Non Recommandé
10
13
14
15
22
3.0
4.0
4.3
4.6
6.7
14
17
18
19
27
4.3
5.2
5.5
5.8
8.2
22
26
27
28
36
6.7
7.9
8.2
8.5
11.0
31
36
39
41
53
9.4
11.0
12.0
12.0
16
20 500 250
300
350
-
50
-
52
.33
.36
.38
.42
8.4
9.1
9.7
10.7
Non Recommandé
10
13
15
20
3.0
4.0
4.6
6.1
14
17
19
25
4.3
5.2
5.8
7.6
22
26
28
34
6.7
7.9
8.5
10.0
30
35
38
50
9.1
11.0
12.0
15.0
24 600 200
250

300
350
-
-
50
-
-
52
.33
.37
.38
.40
.43
.44
8.4
9.4
9.7
10.2
10.9
11.2
Non Recommandé
8
11
12
13
15
17
2.4
3.4
3.7
4.0
4.6
5.2
12
15
17
17
19
21
3.7
4.6
5.2
5.2
5.8
6.4
17
20
23
24
28
30
5.2
6.1
7.0
7.3
8.5
9.2
25
29
31
32
37
41
7.6
8.8
9.4
9.8
11.0
12.5
30 750 150
200

250
300

350
-
-
50
-
-
52
-
.34
.38
.39
.42
.45
.47
.49
8.6
9.7
9.9
10.7
11.4
11.9
12.4
Non Recommandé
-
8
10
11
12
14
15
-
2.4
3.0
3.4
3.7
4.3
4.6
9
12
14
15
16
19
19
2.7
3.7
4.3
4.6
4.9
5.8
5.8
14
16
18
19
21
24
25
4.3
4.9
5.5
5.8
6.4
7.3
7.6
22
24
25
27
29
33
33
6.7
7.3
7.6
8.2
8.8
10.0
10.0
36 900 150
200

250
300

350
-
-
50
-
-
52
-
.38
.42
.43
.47
.51
.53
.56
9.7
10.7
10.9
11.9
13.0
13.5
14.2
Non Recommandé
-
8
10
10
12
15
15
-
2.4
3.0
3.0
3.7
4.6
4.6
9
12
13
14
16
19
19
2.7
3.7
4.0
4.3
4.9
5.8
5.8
14
15
17
18
20
24
24
4.3
4.6
5.2
5.5
6.1
7.3
7.3
21
23
25
25
28
32
32
6.4
7.0
7.6
7.6
8.5
9.8
9.8
  • Les épaisseurs maximales de remblai pour les classes pression sont conformes aux indications du tableau 14 de la norme AWWA C150-96.
  • Les épaisseurs maximales de remblai pour les classes spéciales sont conformes aux indications du tableau 14 de la norme AWWA C150-86.
  • Les dimensions sont soumises aux tolérances de fabrication.
  • Communiquez avec Tuyauteries Canada pour connaître les autres classes spéciales et diamètres disponibles.